Purpose
- Design of a steel structure plus its ancillaries to safe store the load during the transportation and lifting of an element
Design constrains
- Light steel structure
Design data

- Element weight W and geometry G
- Lifting plan
Design
- Each element is verified via Finite Element Analysis and/or via Mechanical Construction Theory formulae in each load case
- The Payload safety is verified in any load case
- An optimization is performed to reduce the packing weight and to increase safety factor until the customer requests are reached